Specials

All specials

IEC 61482-1-1 : 1.0

IEC 61482-1-1 : 1.0

LIVE WORKING - PROTECTIVE CLOTHING AGAINST THE THERMAL HAZARDS OF AN ELECTRIC ARC - PART 1-1: TEST METHODS - METHOD 1: DETERMINATION OF THE ARC RATING (ATPV OR E[BT50]) OF FLAME RESISTANT MATERIALS FOR CLOTHING

International Electrotechnical Committee

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$31.20

$78.00

(price reduced by 60 %)

Table of Contents

FOREWORD<br>1 Scope<br>2 Normative references<br>3 Terms, definitions and symbols<br>&nbsp;&nbsp;&nbsp;3.1 Terms and definitions<br>&nbsp;&nbsp;&nbsp;3.2 Symbols and units<br>4 Principle of the test methods<br>&nbsp;&nbsp;&nbsp;4.1 Test method A<br>&nbsp;&nbsp;&nbsp;4.2 Test method B<br>5 Significance and use of the test methods<br>6 Test apparatus<br>&nbsp;&nbsp;&nbsp;6.1 General<br>&nbsp;&nbsp;&nbsp;6.2 Method A - Arrangement of the two-sensor panels<br>&nbsp;&nbsp;&nbsp;6.3 Method A - Panel construction<br>&nbsp;&nbsp;&nbsp;6.4 Method B - Arrangement of the mannequins<br>&nbsp;&nbsp;&nbsp;6.5 Method B - Mannequin construction<br>&nbsp;&nbsp;&nbsp;6.6 Sensor response<br>&nbsp;&nbsp;&nbsp;6.7 Calorimeter construction<br>&nbsp;&nbsp;&nbsp;6.8 Supply bus and electrodes<br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;6.8.1 General<br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;6.8.2 Electrodes<br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;6.8.3 Fuse wire<br>&nbsp;&nbsp;&nbsp;6.9 Electric supply<br>&nbsp;&nbsp;&nbsp;6.10 Test-circuit control<br>&nbsp;&nbsp;&nbsp;6.11 Data acquisition system<br>7 Precautions<br>8 Specimen preparation<br>&nbsp;&nbsp;&nbsp;8.1 Test specimens<br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;8.1.1 Test specimens for method A: two-sensor panel <br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;test<br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;8.1.2 Test specimens for method B: four-sensor <br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;mannequin<br>&nbsp;&nbsp;&nbsp;8.2 Laundry conditioning of test specimens<br>9 Calibration<br>&nbsp;&nbsp;&nbsp;9.1 Data acquisition system precalibration<br>&nbsp;&nbsp;&nbsp;9.2 Calorimeter calibration check<br>&nbsp;&nbsp;&nbsp;9.3 Arc exposure and apparatus calibration for the <br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;two-sensor panels and the monitoring sensors<br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;9.3.1 Test apparatus<br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;9.3.2 Positioning of the two-sensor panels, mannequins <br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;and monitoring sensors<br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;9.3.3 Apparatus calibration for the two-sensor panels <br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;and monitoring sensors<br>&nbsp;&nbsp;&nbsp;9.4 Confirmation of test apparatus setting<br>10 Test apparatus care and maintenance<br>&nbsp;&nbsp;&nbsp;10.1 Surface reconditioning<br>&nbsp;&nbsp;&nbsp;10.2 Care of sensor panels and mannequins<br>&nbsp;&nbsp;&nbsp;10.3 Care of electrodes<br>11 Test procedures<br>&nbsp;&nbsp;&nbsp;11.1 Test parameters<br>&nbsp;&nbsp;&nbsp;11.2 Sequence of tests<br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;11.2.1 Panels<br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;11.2.2 Mannequins<br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;11.2.3 Test criteria<br>&nbsp;&nbsp;&nbsp;11.3 Initial temperature<br>&nbsp;&nbsp;&nbsp;11.4 Specimen mounting<br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;11.4.1 Method A panels<br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;11.4.2 Method B mannequins<br>&nbsp;&nbsp;&nbsp;11.5 Specimen characteristics<br>&nbsp;&nbsp;&nbsp;11.6 Test protocol<br>12 Interpretation of results<br>&nbsp;&nbsp;&nbsp;12.1 Heat transfer<br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;12.1.1 Determining time zero<br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;12.1.2 Plotting sensor response<br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;12.1.3 Sensor response versus Stoll curve<br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;12.1.4 Determination of heat attenuation factor (HAF)<br>&nbsp;&nbsp;&nbsp;12.2 Determination of breakopen threshold energy, E[BT50]<br>&nbsp;&nbsp;&nbsp;12.3 Arc rating<br>&nbsp;&nbsp;&nbsp;12.4 Visual inspection<br>13 Test report<br>Annex A (normative) Measurement of char length<br>Annex B (informative) Logistic regression technique<br>Annex C (informative) Heat attenuation factor<br>Bibliography

Abstract

Describes test methods to measure the arc thermal performance value of materials intended for use in heat- and flame-resistant clothing for workers exposed to the thermal effects of electric arcs and the function of garments using these materials.

General Product Information

Document Type Standard
Status Current
Publisher International Electrotechnical Committee
Committee TC 78
Supersedes
  • IEC 61482-1 : 1.0

Contact us