AS/NZS 4776.1.1:2008

AS/NZS 4776.1.1:2008

Liquid-chilling packages using the vapour compression cycle Method of rating and testing for performance - Rating

Standards Australia

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$34.32

$78.00

(price reduced by 56 %)

Table of Contents

<toc>
<bookmarktable>
<bookmark index=&apos;0&apos;>
<pageno>1</pageno>
<text>AS/NZS 4776.1.1:2008 LIQUID-CHILLING PACKAGES USING THE VAPOUR COMPRESSION CYCLE - METHOD OF RATING AND TESTING FOR...</text>
<bookmark index=&apos;1&apos;>
<pageno>4</pageno>
<text>PREFACE</text>
</bookmark>
<bookmark index=&apos;2&apos;>
<pageno>5</pageno>
<text>CONTENTS</text>
</bookmark>
<bookmark index=&apos;3&apos;>
<pageno>6</pageno>
<text>1 SCOPE</text>
</bookmark>
<bookmark index=&apos;4&apos;>
<pageno>6</pageno>
<text>2 OBJECTIVE</text>
</bookmark>
<bookmark index=&apos;5&apos;>
<pageno>6</pageno>
<text>3 NORMATIVE REFERENCES</text>
</bookmark>
<bookmark index=&apos;6&apos;>
<pageno>6</pageno>
<text>4 DEFINITIONS</text>
<bookmark index=&apos;7&apos;>
<pageno>6</pageno>
<text>4.1 Air-cooled condenser</text>
</bookmark>
<bookmark index=&apos;8&apos;>
<pageno>6</pageno>
<text>4.2 Bubble point</text>
</bookmark>
<bookmark index=&apos;9&apos;>
<pageno>7</pageno>
<text>4.3 Coefficient of performance (COP)</text>
</bookmark>
<bookmark index=&apos;10&apos;>
<pageno>7</pageno>
<text>4.4 Condenser heat rejection capacity</text>
</bookmark>
<bookmark index=&apos;11&apos;>
<pageno>7</pageno>
<text>4.5 Cooling capacity</text>
</bookmark>
<bookmark index=&apos;12&apos;>
<pageno>7</pageno>
<text>4.6 Dew point</text>
</bookmark>
<bookmark index=&apos;13&apos;>
<pageno>7</pageno>
<text>4.7 Evaporator</text>
</bookmark>
<bookmark index=&apos;14&apos;>
<pageno>7</pageno>
<text>4.8 Fouling factor</text>
</bookmark>
<bookmark index=&apos;15&apos;>
<pageno>7</pageno>
<text>4.9 Fouling factor allowance</text>
</bookmark>
<bookmark index=&apos;16&apos;>
<pageno>7</pageno>
<text>4.10 Liquid-chilling package</text>
</bookmark>
<bookmark index=&apos;17&apos;>
<pageno>7</pageno>
<text>4.11 Liquid-cooled condenser</text>
</bookmark>
<bookmark index=&apos;18&apos;>
<pageno>7</pageno>
<text>4.12 Liquid refrigerant temperature</text>
</bookmark>
<bookmark index=&apos;19&apos;>
<pageno>7</pageno>
<text>4.13 Part-load value (PLV)</text>
</bookmark>
<bookmark index=&apos;20&apos;>
<pageno>7</pageno>
<text>4.14 Part-load value, integrated (IPLV)</text>
</bookmark>
<bookmark index=&apos;21&apos;>
<pageno>7</pageno>
<text>4.15 Part-load value, non-standard (NPLV)</text>
</bookmark>
<bookmark index=&apos;22&apos;>
<pageno>8</pageno>
<text>4.16 Saturated discharge temperature</text>
</bookmark>
<bookmark index=&apos;23&apos;>
<pageno>8</pageno>
<text>4.17 Total power input</text>
</bookmark>
<bookmark index=&apos;24&apos;>
<pageno>8</pageno>
<text>4.18 Published ratings</text>
</bookmark>
</bookmark>
<bookmark index=&apos;25&apos;>
<pageno>8</pageno>
<text>5 RATING REQUIREMENTS</text>
<bookmark index=&apos;26&apos;>
<pageno>8</pageno>
<text>5.1 Test requirements</text>
</bookmark>
<bookmark index=&apos;27&apos;>
<pageno>8</pageno>
<text>5.2 Standard rating conditions</text>
</bookmark>
<bookmark index=&apos;28&apos;>
<pageno>8</pageno>
<text>5.3 Application rating conditions</text>
</bookmark>
<bookmark index=&apos;29&apos;>
<pageno>8</pageno>
<text>5.4 Part-load rating</text>
</bookmark>
<bookmark index=&apos;30&apos;>
<pageno>9</pageno>
<text>5.5 Determination of part-load performance</text>
</bookmark>
</bookmark>
<bookmark index=&apos;31&apos;>
<pageno>10</pageno>
<text>6 PUBLISHED RATINGS</text>
<bookmark index=&apos;32&apos;>
<pageno>10</pageno>
<text>6.1 Compliance</text>
</bookmark>
<bookmark index=&apos;33&apos;>
<pageno>10</pageno>
<text>6.2 Fouling allowance</text>
</bookmark>
<bookmark index=&apos;34&apos;>
<pageno>11</pageno>
<text>6.3 Standard ratings</text>
</bookmark>
<bookmark index=&apos;35&apos;>
<pageno>11</pageno>
<text>6.4 Nameplate information</text>
</bookmark>
</bookmark>
<bookmark index=&apos;36&apos;>
<pageno>12</pageno>
<text>7 RATING TOLERANCES</text>
<bookmark index=&apos;37&apos;>
<pageno>12</pageno>
<text>7.1 General</text>
</bookmark>
<bookmark index=&apos;38&apos;>
<pageno>12</pageno>
<text>7.2 Allowable tolerance</text>
</bookmark>
<bookmark index=&apos;39&apos;>
<pageno>12</pageno>
<text>7.3 Full-load example in COP</text>
</bookmark>
<bookmark index=&apos;40&apos;>
<pageno>12</pageno>
<text>7.4 Part-load example in COP</text>
</bookmark>
</bookmark>
</bookmark>
</bookmarktable>
</toc>

Abstract

Establishes methods of rating the performance of factory-made liquid-chilling packages using the vapour compression cycle.

Scope

This Standard sets out a procedure for rating liquid-chilling packages used in applications with temperatures as described in Clause 5.3 and as defined in Clause 4.12. This Standard covers air- and water-cooled liquid-chilling packages of cooling capacity 350 kW and above.
This Standard does not cover -
(a) liquid-chilling packages driven by other than electric motors;
(b) air-cooled liquid-chilling packages with centrifugal fans;
(c) liquid-chilling packages with remote condensers; and
(d) liquid-chilling packages for fluids other than water.
This Standard covers full-load and part-load ratings to allow for an energy analysis of the unit in different applications.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
Committee ME-086
Supersedes
  • DR 07278

Contact us